LP GAS EQUIPMENT PRODUCT GUIDE Ver.1.0
24/120

How to Use the Catalog23*This catalog contains information about products that is current as of May 31, 2019.Products may differ from the content of the catalog due to speci cation changes and new printings. We thank you for your understanding.How to Use the CatalogWe have revised the structure of our general catalog in order to make our catalogs more ef cient.The YAZAKI LP Gas Equipment General Product Guide introduces various LP gas equipments handled by YAZAKI Energy System.You can also easily access our website from your smartphone, in order to more conveniently view product information and drawings on the work site.Furthermore, we have included a Technical Documents page at the end, featuring useful information such as related regulations, how to select equipments, and how to install them.We hope it will be a help for your business.Title PageProduct IntroductionPage■ Product Categories■ Product Groups■ IndexThis index tab makes it easier to search for product categories.The applicable group is made easily visible with blue-green coloration.■ Product PictureIf there are multiple variations, then representative products are listed.Includes related matters and additional information about products.Includes characteristics and an explanation of the product.Gas MetersAlarmsControllers /Shutoff ValvesBulks /VaporizersRegulatorsHoses /Gas CocksTechnical Documents■ Categories ■Gas Leak Alarm ■No-voltage Output Gas Leak Alarm ■Voltage Output Gas Leak Alarm ■Dual Output Gas Leak Alarm ■CO Alarm ■Ventilation warning Alarm for Commercial ■Detector ■Gas Leak Alarm Adapter ■Gas Leak Alarm AuxiliariesLP Gas Leak AlarmsVarious detectors P. 37Various detectors P. 37Various detectors P. 37Various detectors P. 37Various detectors P. 37CO Alarm P. 36CO Alarm P. 36CO Alarm P. 36CO Alarm P. 36CO Alarm P. 36Household use CO alarmCommercial Use Ventilation Alarm P. 36Commercial Use Ventilation Alarm P. 36Commercial Use Ventilation Alarm P. 36Commercial Use Ventilation Alarm P. 36Commercial Use Ventilation Alarm P. 36Ventilation alarm best suited for commercial facilitiesGas Leak Alarm Adapter P. 38Gas Leak Alarm Adapter P. 38Gas Leak Alarm Adapter P. 38Gas Leak Alarm Adapter P. 38Gas Leak Alarm Adapter P. 38Converts alarm output signalsGas Leak Alarm Auxiliaries P. 38Gas Leak Alarm Auxiliaries P. 38Gas Leak Alarm Auxiliaries P. 38Gas Leak Alarm Auxiliaries P. 38Gas Leak Alarm Auxiliaries P. 38Links alarms with gas meters wirelesslyChoose the right LP gas leak alarm for your applicationLP Gas Leak AlarmsGas MetersRegulatorsHoses / Gas CocksTechnical DocumentsBulks / VaporizersControllers /Shutoff ValvesAlarmsNo-voltage Output Gas Leak Alarm P. 34No-voltage Output Gas Leak Alarm P. 34No-voltage Output Gas Leak Alarm P. 34No-voltage Output Gas Leak Alarm P. 34No-voltage Output Gas Leak Alarm P. 34Links with microcomputer gas metersYF-434GGas Leak Alarm P.33Gas Leak Alarm P.33Gas Leak Alarm P.33Gas Leak Alarm P.33Gas Leak Alarm P.33Alarms usable in general householdsYF-005NTX-611HCO-FL1SP-220YSC-01BYSC-29AYSC-29BVoltage Output Gas Leak Alarm P. 35Voltage Output Gas Leak Alarm P. 35Voltage Output Gas Leak Alarm P. 35Voltage Output Gas Leak Alarm P. 35Voltage Output Gas Leak Alarm P. 35Links with shutoff valve controllerYF-433FYZ-222Dual Output Gas Leak Alarm P. 35Dual Output Gas Leak Alarm P. 35Dual Output Gas Leak Alarm P. 35Dual Output Gas Leak Alarm P. 35Dual Output Gas Leak Alarm P. 35Voltage + No Voltage, for commercial facilitiesYF-313AYZ-165CUsed for gas leaks and CO detection323536LP Gas Leak AlarmsGas MetersRegulatorsHoses / Gas CocksTechnical DocumentsBulks / VaporizersControllers /Shutoff ValvesAlarmsCO Alarm / Ventilation Warning Alarm for CommercialVoltage Output Gas Alarm / Dual Output Gas AlarmModelYZ-165CTarget GasCO (carbon monoxide) in not fully combusted exhaust gasSensorElectrochemical SensorGas Density for DetectionCO Hb density of 20% or equivalent in human blood*Alarm Method1) Display Yellow (ventilation) Lamp Flashing (1 second period)2) Alarm Sound Sound Effect + Voice Alarm more than 70 dB/mOperating Temperature Range0ºC to +50ºCPower Supply3 V Lithium battery × 1Battery Life6 years after installationExternal Outputa Contact Output Polarized (DC 24 V, 5 mA) Alarm Instantly ONBuilt-in Function● Speaker Wire Breakdown Monitor Function ● Battery Voltage Monitor Function ● Alarm Stop Function ● Expiration Notication Function● Sound Circuit Monitor Function ● Voice Message Check Function ● Alarm History Ventilation Display Function● Failure Monitoring FunctionInstallation MethodHanging (using hook)External DimensionsH100×W75×D20.5 (mm)WeightApprox. 100 gPackaging Unit20 pcs* Alarm will be issued immeidately when the density of more than 2,000 ppm is detected twice consecutively (Approx. 10 seconds).ModelYZ-222Target GasIncomplete Combustion Exhaust Gas from Liqueed Petroleum Gas Combustion EquipmentSensorElectrochemical SensorGas Density for DetectionLow Concentration Over 50 ppm - 250 ppmHigh Concentration Low concentration - 550 ppmAlarm MethodLow Concentration Yellow (CO Alarm) Lamp ashes slowly (1 ash every 5 seconds).After 2 minutes, synthetic voice alarm (more than 70 dB/m) Automatic recovery typeHigh Concentration Yellow (CO Alarm) Lamp ashes slowly (1 ash every 1 second).Synthetic voice alarm (more than 70 dB/m) Automatic recovery typeResponse timeLow Concentration: Within 10 Minutes High Concentration: Within 5 MinutesOperating Temperature0ºC to +50ºCPower SupplyDC 3V (Lithium battery)External Outputa-contact (Open collector)During Failure and Monitoring OFF During CO Alarm ONTransmitting standard delay time 34 secondsSpecial functions● Energizing Initial Alarm Prevention Timer ● Expiration Notication Function● Failure Diagnosis FunctionExternal DimensionsH100×W75×D20.5 mmWeightApprox. 100 gPackaging Unit20 pcsThis alarm complies with the Authorized LP Gas Distributor System by linking to the meter.Compact, doesn’t sound early, noties reliably with an easy to understand alarm sound and voice.● Specications ● Specications ● Request regarding installation CO AlarmYZ-222Ventilation Warning Alarm for CommercialYZ-165CPlease submit a checklist and emergency contact list concerning the “Ventilation Warning Alarm for Commercial” sales regulations. (First time only)ModelYF-433FYF-433F (S)Detection PrincipleContact Combustion Type Gas SensorGas Density for DetectionLess than 1/4 of lower limit for gas explosionAlarm MethodTime-Lag Alarm, Automatic ResetAlarm Lamp (LED: Red)Buzzer Alarm "Peeppo Peeppo" (Electric Buzzer more than 70 dB/m)Operating Temperature-10ºC to +40ºCPower SupplyAC 100 V 50/60 HzPower ConsumptionDuring monitoring: Approx. 0.8 W, During alarm: Approx. 1.1 WExternal OutputConnection MethodFront Panel Terminal BlockOutput SignalTwo-step voltage two wire type Monitoring DC 6 V During alarm DC 0-6-12 V Failure DC 0 VBuilt-in CircuitMuting Circuit Enabled at Power-on (Approx. 5 seconds)Alarm Time-Lag Circuit (Approx. 15 seconds)Inspection mode (1 minute)FunctionReplacement Notication, Alarm Sound StopFailure NoticationFrame Ground TerminalFront Panel Terminal BlockPower Plug Cable2.5 m(Spare Socket Included)0.35 mExternal DimensionsH117×W70×D29 mm WeightApprox. 220 gApprox. 150 gPackaging Unit20 pcs● Eco Mark ProductModelYF-432Detection PrincipleContact Combustion Type Gas SensorGas Density for DetectionLess than 1/4 of lower limit for gas explosionAlarm MethodImmediate Alarm Automatic ResetAlarm Lamp (LED: Red)Buzzer Alarm (Electric Buzzer more than 70 dB/m)Operating Temperature-10ºC to +40ºCPower SupplyAC 100 V 50/60 HzPower ConsumptionDuring monitoring: Approx. 2W, During alarm: Approx. 2WExternal OutputConnection MethodBack panel plugOutput SignalTwo-step voltage two wire type Monitoring DC 6 V During alarm DC 12 V Failure DC 0 VExternal DimensionsH68×W86×D37 (mm)WeightApprox. 200 gOptionYA-300 (Embedded Socket)YA-301 (Switch Box)Packaging Unit40 pcsNoties you with an easy to understand buzzerNoties you with an easy to understand buzzer and lampIn-Wall Mount Type Alarm● SpecicationsModelYF-417CDetection PrincipleContact Combustion Type Gas SensorGas Density for DetectionLess than 1/4 of lower limit for gas explosionAlarm MethodImmediate Alarm Automatic ResetAlarm Lamp (LED: Red)Buzzer Alarm (Electric Buzzer more than 70 dB/m)Operating Temperature-10ºC to +40ºCPower SupplyDC 24 V (Operating voltage range DC 17 - 40 V)Power ConsumptionDuring monitoring: Approx. 1.5 W, During alarm: Approx. 1.7 WBuilt-in Circuit● Muting circuit enabled at power-on (Approx. 40 seconds)● Alarm time-lag circuit (Approx. 25 seconds)● Bridge Circuit● External Output Signal Short Protection Circuit● Gas Sensor Failure Monitor Circuit● Electrical Circuit Failure Monitor FunctionExternal OutputConnection MethodRotate to Hook to Mounting BaseOutput SignalTwo-step voltage two wire type Monitoring DC 6 V During alarm DC 0-6-12 V Signal Wire Disconnected DC 0 VDC 0 VExternal Dimensionsφ120×34 (mm)WeightApprox. 150 gOptionSH5910 (Mounting Base: Commercial Item Made by PANASONIC)Packaging Unit40 pcs● Specications● Specications Voltage Output Gas Leak AlarmYF-433F(Buzzer Type)Voltage Output Gas Leak AlarmYF-417C(24 V Power Supply Type)Voltage Output Gas Leak AlarmYF-432 (Built-in Type)A commercial alarm suitable for places exposed to waterModelYF-313ADetection PrincipleContact Combustion Type Gas SensorGas Density for DetectionMore than 1/100 and Less than 1/4 of lower limit for gas explosionAlarm MethodImmediate Alarm Automatic ResetAlarm Lamp (LED: Red)Buzzer/voice alarm* (Electric buzzer more than 70 dB/m)Operating Temperature-10ºC to +40ºCPower SupplyAC 100 V 50/60 HzPower ConsumptionDuring monitoring: Approx. 1 W, During alarm: Approx.1.7 WExternal OutputConnection MethodBack panel connectorVoltage outputTwo-step voltage two wire type(Monitoring: DC 6 V During alarm DC 12 V: Failure: DC 0 V)No-Voltage OutputOpen collector of phototransistor(During monitoring: OFF, During alarm ON-OFF at 10 second interval, Failure: OFF)Standard Time-LagApprox. 34 seconds (without voltage) 0 second (with voltage)Power Plug Cable2.5 m (Spare socket included)Connection method between main and sensor unitMaximum Length of Signal Wire 200 m (0.3 mm2)Number of Sensor Unit to be Connected: 1External DimensionsMain Unit: H118×W69×D23.5 mm (without protrusion)Sensor Unit: H90×W43×D25.5 mm (without protrusion)WeightMain Unit: Approx. 205 g Sensor Unit: Approx. 55 gPackaging Unit20 pcs*Alarm sound can be changed by using the inspection/alarm stop switch● Specications Dual Output Gas Leak AlarmYF-313A(Commercial)■ Feature■ Speci cation Table■ Comments/Notices■ Product Name /Model■ Listed Page■ Listed Products■ Index

元のページ  ../index.html#24

このブックを見る